Azure AD Connect 1.1.105.0 is GA

On February 18th  2016 Microsoft released a significant update to Azure AD Connect, version 1.1.105.0. It adds some capabilities and improves on others. For me this is a core piece of the puzzle today and in the future for many of my plans to optimize the future IT Infrastructure & DevOps. Even when politics seem hell bound on slowing you down and cause a serious delay and missed opportunities this piece of technology is key in breaking through those barriers and keep moving ahead.

So what’s in the box with version  1.1.105.0

  • Automatic upgrade feature for Express settings customers.
    Support for the global admin using MFA and PIM in the installation wizard.
  • We can change the user’s sign-in method after initial install.
  • We can now set Domain and OU filtering in the installation wizard. As a secondary benefit this means we can now connect to forests where not all domains are available.
  • We get a Scheduler is built-in to the sync engine.

Some preview features are now GA:

We get one new preview features which is going to be a hit in world where patience disappeared from the equation:

  • The default sync interval is now 30 minutes instead of 3 hours before. this is configurable now in the scheduler.

It also fixes the following issues:

  • The verify DNS domains page didn’t always recognize the domains.
  • Prompts for domain admin credentials when configuring ADFS.
  • On-premises AD accounts are not recognized by the installation wizard when they are in a domain with a different DNS tree than the root domain.

Grab the latest version of Azure AD Connect here.

Shared VHDX In Windows 2016: VHDS and the backing storage file

Introduction into the VHD Set

I have talked about the VHD Set with a VHDS file and a AVHDX backing storage file in Windows Server 2016 in a previous blog post A first look at shared virtual disks in Windows Server 2016. One of the questions I saw pass by a couple of times is whether this is still a “normal VHDX” or a new type of virtual disk. Well the VHDS files is northing but a small file containing some metadata to coordinate disk actions amongst the guest cluster nodes accessing the shared virtual disk. The avhdx file associated with that VHDS file is an automatically managed dynamically expanding or fixed virtual disk. How do I know this? Well I tested it.

There is nothing that preventing you from copying or moving the avhdx file of a VHD Set that not in use. You can rename the extension from avhdx to vhdx. You can attach it to another VM or mount it in the host and get to the data. In essence this is a vhdx file. The “a” in avhdx stands for automatic. The meaning of this is that an vhdx is under control of the hypervisor and you’re not supposed to be manipulating it but let the hypervisor handle this for you. But as you can see for yourself if you try the above you can get to the data if that’s the only option left. Normally you should just leave it alone. It does however serve as proof that the VHD Set uses an standard virtuak disk (VHDX) file.

I’ll demonstrate this with an example below.

Fun with a backing storage file in a VHD Set

Shut down all the nodes of the guest cluster so that the VHD Set files are not in use. We then rename the virtual disk’s extension avhdx to vhdx.

image

You can then mount it on the host.

image

And after mounting the VHDX we can see the content of the virtual disk we put there when it was a CSV in that guest cluster.

image

We add some files while this vhdx is mounted on the host

image

Rename the virtual disk back to a avhdx extension.

image

We boot the nodes of the guest cluster and have a look at the data on the CSV. Bingo!

image

I’m NOT advocating you do this as a standard operation procedure. This is a demo to show you that the backing storage files are normal VHDX files that are managed by the hypervisor and as such get the avhdx extension (automatic vhdx) to indicate that you should not manipulate it under normal circumstances. But in a pinch, it a normal virtual disk so you can get to it with all options and tools at your disposal if needed.

Load balancing UDP for a RD Gateway farm with a KEMP Loadmaster

When implementing load balancing for RD Gateway we must take care not to forget load balancing the UDP traffic. Now your RDP Connection will still work over HTTPS alone if you forget this, but you’ll miss out on the benefits.

  • Better experience of bad, unreliable network connections with high packet loss
  • Better experience with high end graphics and in general a better graphical experience over WAN links.

As many people have load balanced their gateways since Windows Server 2008 (R2) when UDP was not into play yet and as things work without people might forget. The most important thing you need to know is that when leveraging UDP for RDP 8/8.1 the UDP session traffic has to leverage Direct Server Return (DSR) for the real servers configuration when we configure load balancing for a RD gateway farm with a KEMP Loadmaster. I’m focusing on the UDP part here, not the HTTPS part. That’s been done enough and the Kemp info on that is sufficient. The UDP part could do with some extra info.

The reason for this is that when UDP is leveraged for high end graphics we want to avoid sending all that graphical network traffic the load balancer. There is no real added value being performed there in this UDP use case but the load might get quite high. This is where DSR is leveraged wen configuring the Loadmaster. That means we also need to configure our real servers to uses Direct Return as the forwarding method. When you forget this you’ll lose UDP with RDP 8.1 but you might not notice immediately. If you’re not looking for it as the HTTP connection alone will let you connect and work, albeit with a reduced experience.

To read more on why it’s done this way (even if it seems complex and has drawbacks) see http://kemptechnologies.com/ca/white-papers/direct-server-return-it-you/ you’ll notice that for graphics it is great idea. By selecting Direct Server Return as the  forwarding method (see later) changes the destination MAC address of the incoming packet on the fly (very fast) to the MAC address of one of the real servers. When the packet reaches the real server it must think it owns the VS IP address, which it doesn’t. So we use the loopback adapter to let the real server reply as if it does but we don’t respond to ARPs as that would cause issues with the load balancer who has the real IP of the virtual service. That’s where the 254 metric we configure in the demo below comes into play.  Note that  the real server responds over it normal NIC. Which is great and it helps with firewall rules not ruining the party. That’s why with DSR which leverages the the loopback adapter on the RD Gateway servers also requires you to configure the weak host / strong host behavior for the network configuration on those servers, it’s not answering itself! I’ll not go into details on this here but basically since Windows Vista and Windows Server 2008 the security model has change from weak host to strong host. This means that a system (that is not acting as a router) cannot send or receive any packets on a given interface unless the destination/source IP in the packet is assigned to the interface. In the “weak host” model, this restriction does not apply. Read more about this here. Let’s walk through this UDP/DSR/weak host setup & configuration.

On your Loadmaster you’ll create a virtual service for UDP traffic.

  • Select Virtual Services > Add New.
  • Enter the IP address of your RD Gateway Farm
  • Set 3391 as the Port.
  • Select udp for the Protocol.
  • Click Add this Virtual Service.

Open up the Standard Options to configure those

image

  • We don’t need layer 7 as the UDP connections are tied to the HTPP connection and they will spawn and die with that one.
  • We select Source IP Address as the Persistence Mode as the RD Gateway needs persistence to guarantee the connection stay together on the same RD Gateway server. Set the time out value no to high so it isn’t remembered to long.
  • We select least connections as that’s the best option in most cases, let the farm node with the least load take on new connections. This is handy after down time for example.

Now head over to the Real Servers section

image

  • Make sure the Real Server Check parameters is set to ICMP ping, which is what the LoadMaster uses to check if the RD Gateway servers are alive.
  • Click Add New to add an  RD Gateway server, you’ll do this for each farm member.

image

  • Enter the Real Server Address for each RD Gateway.
  • Enter 3391 as the Port.
  • Select Direct return as the Forwarding method.
  • Click Add This Real Server.

When you’re done it looks like this:

image

So now we need to check if the real servers are seen as on line and healthy …

image

If one RD Gateway server is down or has an issue you see this … no worries the LoadMaster sends all clients to the other farm member server.

image

Configure the  RD Gateway farm servers to work with DSR

We’re not done yet, we need to configure our RD Gateway servers in the farm to work with DSR.

Go to Device Manager, right-click on the computer name and select Add legacy hardware

image

Click next on the welcome part of the wizard …

image

Select “Install the hardware that I manually select from a list (Advanced)” and click Next …image

Scroll down to network adapters, select it and click Next …image

Under Manufacturer choose Microsoft and as Network Adapter scroll down to Microsoft KM-TEST Loopback Adapter, select it and click Next.

image

Click Next to install it …image

image

Click next to close the Wizard.image

 

Now go to  and change the name so you can easily identify the loopback adapter …imageimage

In the properties of the loopback adapter we disable everything we don’t need. In this case, we only need IPV4 and nothing else. We also need to configure the TCP/IP settings for the loopback adapter. So open up the TCP/IP v4 properties of that NIC …image

Enter the IP address of the Virtual Service for UDP on the load master and, very important enter a subnet mask of 255.255.255.255 for the loopback address. It’s a subnet of 1 host, the VIP IP address. Do not enter a gateway!

image

Now go to the advanced setting and deselect Automatic metric and fill out 254. This step prevents the server to respond to ARP requests for the MAC of the VIP with the MAC of the loop back adapter.

image

Also uncheck “Register this connection”s address in DNS” to avoid any name resolution problems for the real servers.

image

Finally disable NETBIOS over TCP/IP.

image

What we are doing with all the above is preventing any issues with normal network traffic to this real servers being affected by the loopback adapter who’s one and only function is to enable DSR and nothing else. It’s a bit “paranoid” but it pays to be and prevent problems.

Dealing with Strong Host / Weak Host setting in W2K8 and higher

We now still need to deal with the strong host security model and allow the LAN interface to receive traffic from the KEMP and allow the KEMP to receive and send traffic form/to the LAN interface. This is done by executing the following commands:

netsh interface ipv4 set interface LAN weakhostreceive=enabled
netsh interface ipv4 set interface KEMP-DSR-LOOPBACK weakhostreceive=enabled
netsh interface ipv4 set interface KEMP-DSR-LOOPBACK weakhostsend=enabled

That’s it. You should now have HTTP/UDP connections in your RD Gateway monitoring when using a load balancer and set it up correctly.  Remember if this isn’t configured correctly you’ll still connect but you lose the benefits the UDP connections offer.

Now another thing you need to be aware of in your RD Gateway configuration is that for UDP  to work with DSR is that the UDP Transport Settings need to be configured for “all unassigned” IP addresses. Other wise DRS won’t work and you’ll lose UDP. This make sense, you’ll receive traffic on the VIP on your real servers. It’s just like DSR with a web server where in IIS you’ll bind both the LAN and the loopback adapter to port 80 or 443 for the site.

image

We can see that one client is connected via RDSGW01 to two servers (Viking and Spartan) leveraging HTTP and UDP. The load balancing is done via the KEMP Loadmasters in  geo-redundant fashion.

image

Yes, my geo load balanced RD Gateway Server farms are providing UDP support for the servers and clients we  RDP in to.

image

Combined with those servers and clients being spread amongst the sites provides for enough business continuity to keep the shop running when a site fails, so it’s more than just connectivity!

Upgrade the firmware on a Brocade Fibre Channel Switch

NOTE: content available as pdf download here.

Upgrade the firmware on a Brocade Fibre Channel Switch

In order to maintain a secure, well-functioning fibre channel fabric over the years you’ll need to perform a firmware upgrade now and again. Brocade fibre channel switches are expensive but they do deliver a very solid experience. This experience is also obvious in the firmware upgrade process. We’ll walk through this as a guide on how to upgrade the firmware on a Brocade fibre channel switch environment.

Have a FTP/SFTP/SCP server in place

If you have some switches in your environment you’re probably already running a TFTP or FTP server for upgrading those. For TFTP I use the free but simple and good one provided by Solarwinds. They also offer a free SCP/SFTP solution. For FTP it depends either we have IIS with FTP (and FTPS) set up or we use FileZilla FTP Server which also offers SFTP and FTPS. In any case this is not a blog about these solutions. If you’re responsible for keeping network gear in tip top shape you should this little piece of infrastructure set up for both downloads and uploads of configurations (backup/restore), firmware and boot code. If you don’t have this, it’s about time you set one up sport! A virtual machine will do just fine and we back it up as well as we store our firmware and backups on that VM as well. For mobile scenarios I just keep TFTP & FilleZilla Server installed and ready to go on my laptop in a stopped state until I need ‘m.

Getting the correct Fabric OS firmware

It’s up to your SAN & switch vendors to inform you about support for firmware releases. Some OEMs will publish those on their own support sites some will coordinate with Brocade to deliver them as download for specific models sold and supported by them. Dell does this. To get it select your switch version on the dell support site and under downloads you’ll find a link.

clip_image002

That link takes you to the Brocade download page for DELL customers.

clip_image004

Make sure you download the correct firmware for your switch. Read the release notes and make sure you’re the hardware you use is supported. Do your homework, go through the Brocade Fabric OS (FOS) 7.x Compatibility Matrix. There is no reason to shoot yourself in the foot when this can be avoided. I always contact DELL Compellent CoPilot support to verify the version is support with the Compellent Storage Center firmware.

When you have downloaded the firmware for your operating system (I’m on Windows) unzip it and place the content of the resulting folder in your FTP root or desired folder. I tend to put the active firmware under the root and archive older one as they get replaced. So that root looks like this. You can copy it there over RDP or via a FTP client. If the FTP server is running your laptop, it’s just a local copy.

clip_image005

The upgrade process

A word on upgrading the firmware

I you move from a single major level/version to the next or upgrade within a single major level/version you can do non-disruptive upgrades with a High Availability (HA) reboot meaning that while the switch reloads it will not impact the data flow, the FC ports stay online. Everything keeps running, bar that you lose connectivity to the switch console for a short time.

Some non-disruptive upgrade examples:

V6.3.2e to V6.4.3g

V7.4.0a to v7.4.0b

V7.3.0c to v7.4.0b

Note that this way you can step from and old version to a new one step by step without ever needing downtime. I have always found this a really cool capability.

You can find Brocades recommendations on what the desired version of a major release is in https://www.brocade.com/content/dam/common/documents/content-types/target-path-selection-guide/brocade-fos-target-path.pdf

I tend to way a bit with the latest as the newer ones need some wrinkles taken care of as we can see now switch 7.4.1 which is susceptible to memory leaks.

Some disruptive upgrade examples (FC ports go down):

7.1.2b to 7.4.0a

6.4.3.h to 7.4.0b

Our upgrade here from 7.4.0a to 7.4.0b is non-disruptive as was the upgrade from to 7.3.0c to 7.4.0a. You can jump between version more than one version but it will require a reboot that takes the switch out of action. Not a huge issue if you have (and you should) to redundant fabrics but it can be avoided by moving between versions one at the time. IT takes longer but it’s totally non-disruptive which I consider a good thing in production. I reserve disruptive upgrades for green field scenarios or new switches that will be added to the fabric after I’m done upgrading.

Prior to the upgrade

There is no need to run a copy run or write memory on a brocade FC switch. It persists what you do and you have to save and activate your zoning configuration anyway when you configure those (cfgsave). All other changes are persisted automatically. So in that regards you should be all good to go.

Make a backup copy of your configuration as is. This gives you a way out if the shit hits the fan and you need to restore to a switch you had to reset or so. Don’t forget to do this for the switches in both fabrics, which normally you have in production!

You log on switch with your username and password over telnet or ssh (I use putty or kitty)

MySwitchName:admin> configupload

Hit ENTER

Select the protocol of the backup target server you are using

Protocol (scp, ftp, sftp, local) [ftp]: ftp

Hit ENTER

Server Name or IP Address [host]: 10.1.1.12

HIT ENTER

Enter the user, here I’m using anonymous

User Name [user]: anonymous

Hit ENTER

Give the backup file a clear and identifying name

Path/Filename [<home dir>/config.txt]: MySwitchNameConfig20151208.txt

Hit ENTER

Select all (default)

Section (all|chassis|switch [all]): all

configUpload complete: All selected config parameters are uploaded

That’s it. You can verify you have a readable backup file on your FTP server now.

clip_image007

The Upgrade

A production environment normally has 2 fabrics for redundancy. Each fabric exists out of 1 or more switches. It’s wise to start with one fabric and complete the upgrade there. Only after all is proven well there should you move on to the second fabric. To avoid any impact on production I tend plan these early or late in the day also avoiding any backup activity. Depending on your environment you could see some connectivity drops on any FC-IP links (remote SAN replication FC to IP ó IP to FC) but when you work one fabric at the time you can mitigate this during production hours via redundancy.

Log on to first brocade fabric switch with your username and password over telnet or ssh (I use putty or kitty). At the console prompt type

firmwaredownload

This is the command for the non-disruptive upgrade. If you need or want to do a disruptive one, you’ll need to use firmwaredownload –s.

Hit Enter

Enter the IP address of the FTP server (of the name if you have name resolution set up and working)

Server Name or IP address: 10.1.1.12

User name: I fill out anonymous as this gives me the best results. Leaving it blank doesn’t always work depending on your FTP server.

User Name: anonymous

Enter the path to the firmware, I placed the firmware folder in the root of the FTP server so that is

Path: /v7.4.0b

Hit enter

At the password prompt leave the password empty. Anonymous FTP doesn’t need one.

Password:

Hit enter, the upgrade process preparation starts. After the checks have passed you’ll be asked if you want to continue. We enter Y for yes and hit Enter. The firmware download starts and you’ll see lost of packages being downloaded. Just let it run.

clip_image009

This goes on for a while. At one point you’ll see the prom update happening.clip_image011

When it’s done it starts removing unneeded files and when done it will inform you that the download is done and the HA rebooting starts. HA stands for high availability. Basically it fails over to the next CP (Control Processor, see http://www.brocade.com/content/html/en/software-upgrade-guide/FOS_740_UPGRADE/GUID-20EC78ED-FA91-4CA6-9044-E6700F4A5DA1.html) while the other one reboots and loads the new firmware. All this happens while data traffic keeps flowing through the switch. Pretty neat.

When you keep a continuous ping to the FC switch running during the HA reboot you’ll see a short drop in connectivity.

image

But do realize that since this is a HA reboot the data traffic is not interrupted at all. When you get connectivity back you SSH to switch and verify the reported version, which here is now 7.4.0b.

clip_image014

That’s it. Move on to the switch in the same fabric until you’re done. But stop there before you move on to your second fabric (failure domain). It pays to go slow with firmware upgrades in an existing environment.

This doesn’t just mean waiting a while before installing the very latest firmware to see whether any issues pop up in the forums. It also means you should upgrade one fabric at the time and evaluate the effects. If no problems arise, you can move on with the second fabric. By doing so you will always have a functional fabric even if you need to bring down the other one in order to resolve an issue.

On the other hand, don’t leave fabrics unattended for years. Even if you have no functional issues, bugs are getting fixed and perhaps more importantly security issues are addressed as well as browser and Java issues for GUI management. I do wish that the 6.4.x series of the firmware got an update in order for it to work well with Java 8.x.