Fixing Two Small DELL Compellent Hardware Hiccups

Here’s two little tips to solve some small hardware issues you might run into with a Compellent SAN. But first, you’re never on your own with CoPilot support. They are just one phone call away so I suggest if you see these to minor issues you give them a call. I speak from experience that CoPilot rocks. They are really good and go the extra mile. Best storage support I have ever experienced.

Notes

  • Always notify CoPilot as they will see the alerts come in and will contact you for sure Smile. Afterwards they’ll almost certainly will do a quick health check for you. But even better during the entire process they keep an eye on things to make sure you SAN is doing just fine. And if you feel you’d like them to tackle this, they will send out an engineer I’m sure.
  • Note that we’re talking about the SC40 controllers & disk bays here. The newer genuine DELL hardware is better than the super micro ones.

The audible alert without any issues what so ever

We kept getting an audible alert after we had long solved any issues on one of the SANs. The system had been checked a couple of times and everything was in perfect working order. Except for that audible alarm that just didn’t want to quit. A low priority issue I know but every time we walk into the data center we were going “oh oh” for a false alert. That’s not the kind of conditioning you want. Alerts are only to be made when needed and than they do need to be acted upon!

Working on this with CoPilot support we got rid of it by reseating the upper I/O module. You can do this on the fly – without pulling SAS-cables out or so, they are redundant, as long as you do it one by one and the cabling is done right (they can verify that remotely for you if needed).

image

But we got lucky after the first one. After the “Swap Clear” was requested  every warning condition was cleared and we got rid of the audible alert beep!  Copilot was on the line with us and made sure all paths are up and running so no bad things could happen. That’s what you have a copilot for.

Front panel display dimming out on a Compellent Disk Bay

We have multiple Compellent SANs and on one of those we had a disk bay with a info panel that didn’t light up anymore. A silly issue but an annoying one as this one also show you the disk bay ID.

image

Do we really replace the disk bay to solve this one? As that light had come on and of a couple of time it could just be a bad contact so my colleague decided to take a look. First  he removed the protective cover and then, using some short & curved screw drivers, he took of the body part. The red arrow indicates the little latch that holds the small ribbon cable in place.

image

That was standing right open. After locking that down the info appeared again on the panel. The covers was screwed on again and voila. Solved.

Upgrading Your DELL Compellent Storage Center Firmware (Part 1)

This is Part 1 of this blog. You’ll find Part 2 over here

Well the Compellent firmware 6.3.10 has gone public and it’s time to put it on our systems. 6.3 brings interesting features like ODX and UNMAP to us Windows Server 2012 Hyper-V users. It also introduces some very nice improvements to synchronous replication and Live Volumes. But’s those are matters for other blog posts. Here We’ll focus on the upgrade.

In part 1 we’ll look at how we prepare the Compellent to be ready to apply the upgrade. We make sure on our side we have no outstanding issues on the SAN. Then we made sure we upgraded Enterprise Manager and Replay Manager to the latest versions. At this time of writing that is EM 6.3.5.7 and RM 7.0.1.1. We could do this prior to the firmware upgrade because 6.2.2. is also supported by these versions. Once we established all was working well with this software we contacted CoPilot to check our systems (the check it’s health an applicability as well). When all is in order they’ll release the firmware to us. Then It’s time to run a check for update on the systems.

Log in to your Compellent system and navigate to the Storage Management menu. Click on “System”, select Update and finally click on “Check for Update”.
image

The tool will check for updates.

image

If no new firmware has been released to your systems you’ll see this.image

If new firmware has been released you see this in the update status.image

This also shows in the Storage Center GUI

image

Downloading the update.

image

The download takes a while. Once it’s done you’ll see that the update is ready to install. Note that this update is non service affecting in OUR case (green arrow). We won’t install it yet however. We’ll look at the details & validate the components. Due diligence pays off Winking smileimage

Click on details to get some more information about what’s in the update. image

You can see that our disk and enclosure firmware is up to date already from a previous update. The ones related to 6.3.10 are mandatory( required, not optional). When done, hit Return.

We now select “Validate Components” to make sure we’re good to go and won’t get any surprises. Trust but verify is one of our mantras.image

image

So now we are ready to run the update.  We’ll leave that for Part 2.